Manufacturer of Petroleum Test Equipment since 1873

Product   

 Oxidation Stability of Gasolines - OBA 2 & PA5 (semi-automatic)


Main Unit   

13-1664

 

OBA 2 - Oxidation Test Arrangement

OBA 2 - Oxidation Test Arrangement

(Liquid Bath with 4 vessels, 4 safety kits and 4 manometers)

Induction Period of Gasoline:
ASTM D 525 (DIN 51 780) - FTM 791-3352 - IP 40 -
ISO 7536 - JIS K2287 (BS 4347)

Potential Residue of Aviation Fuels:
ASTM D 873 - FTM 791-3354 - IP 138 - JIS K2276
(BS 4456, DIN 51 799)

Consisting of:

4 programmable manometers PA5-OBA:
for automatic determination of the Oxidation Stability or Induction Period, Potential Residue and Storage Stability.
The instrument checks the leakage stability of the pressure vessel first and then switches automatically to the induction period test.
Data can be transferred via an USB interface to a PC (software & cable included).
The software allows to monitor the numerical and graphical data on the screen.

4 oxidation vessels:
of stainless steel, leak free closure possible without the aid of tools , pressure certificate from TÜV for 104 bar static pressure, burst disk 15 bar and burst disk protection shield, one test glass with cover for each bomb. For test temperatures above 100 °C Petrotest® can not accept responsibility.

4 pressure-peak damping devices (Safety Kit):
flame arrester, connecting line, manometer-terminal and filling valve.

4-place liquid bath:
of stainless steel, capacity 45 liters , Thermostat-Head with digital indication, holder panel for four terminals for manometers and valves and two side panels to rest bombs not in use and pressure charging line.

Power supply: 230 V, 50/60 Hz

 

13-1665

 

OBA 2 - Oxidation Test Arrangement

(Liquid Bath with 4 vessels, 4 safety kits and 4 manometers)
Power supply: 115 V, 50/60 Hz

 


13-1656

 

OBA 2 (dual) - Oxidation Test Arrangement

(Liquid Bath with 2 vessels, 2 safety kits and 2 manometers)
Otherwise like 13-1664
Power supply: 230 V, 50/60 Hz

 

13-1657

 

OBA 2 (dual) - Oxidation Test Arrangement

(Liquid Bath with 2 vessels, 2 safety kits and 2 manometers)
Power supply: 115 V, 50/60 Hz

 

16-0720

 

Drain Cock for thermostatic baths (G¼")

 



13-1666

 

OBA 2/T - Oxidation Test Arrangement

(Dry-Heat Bath with 4 vessels, 4 safety kits and 4 manometers)

4-place Dry-Heat Bath:
of stainless steel housing, aluminum block with 4 wells, PID-Regulator with digital setting and four digit indication, control thermometer, pressure charging line and holder for four manometer-terminals.

Otherwise like 13-1664
Power supply: 230 V, 50/60 Hz

 

13-1667

 

OBA 2/T - Oxidation Test Arrangement

(Dry-Heat Bath with 4 vessels, 4 safety kits and 4 manometers)
Power supply: 115 V, 50/60 Hz

 


13-1658

 

OBA 2/T (dual) - Oxidation Test Arrangement

(Dry-Heat Bath with 2 vessels, 2 safety kits and 2 manometers)
Otherwise like 13-1666
Power supply: 230 V, 50/60 Hz

 

13-1659

 

OBA 2/T (dual) - Oxidation Test Arrangement

(Dry-Heat Bath with 2 vessels, 2 safety kits and 2 manometers)
Power supply: 115 V, 50/60 Hz

 




Options & Accessories   

17-0230

 

Tool Set - OBA

13-0547 & 17-0231

makes it easier to open & close pressure vessels
Consisting of:
1 fabric tape wrench
1 table mounted rack

 



13-2122

 

Digital Manometer PA5-OBA (manufacturer certified)

Like 13-2121 but:
with manufacturer's calibration certificate

 

13-2123

 

Digital Manometer PA5-OBA (official certified)

Like 13-2121 but:
with official (DKD) calibration certificate

 

13-2124

 

Sensor Pt1000 (PA5) (for dry-baths or as spare part)

Sensor-Retrofit-Set for dry-baths (PA5-Dry)

to monitor the bath temperature
(temperature range 0 to 200°C, resolution 0.1°C, class 1/3 B).
(not suitable for PA-RBOT or REID)

 

13-3128

 

Sensor-Retrofit-Set for dry-baths (PA5-Dry)

Sensor-Retrofit-Set for dry-baths (PA5-Dry)

to use a bath temperature sensor with an older dry-heat bath.
It includes one Pt1000 and the upgrade of a bath (details on request)  
(not suitable for PA-RBOT or REID)

 

13-3129

 

Sensor-Retrofit-Set for liquid baths (PA5-Liquid)

Sensor-Retrofit-Set for liquid baths (PA5-Liquid)

to use a bath temperature sensor in a liquid bath with an older oxidation vessel.
It includes one Pt1000 with connecting kit and the upgrade of a vessel (details on request)  
(not suitable for PA-RBOT or REID)

 

13-3130

 

Sensor-Set (PA5) (for liquid baths)

Sensor-Set (PA5) (for liquid baths)

It includes one Pt1000 bath temperature sensor with connecting kit for the oxidation vessel
(not suitable for PA-RBOT or REID)

 

13-2135

 

PC-Software Module - PA5 Professional

Dongle with licence key for Pro-Software

dongle with license key (USB-stick)

 

13-2125

 

PC-Data-Cable RS232 (PA power)

RS232 data & power cable set

for data transfer & power supply (100-240 V, 50/60 Hz)
supplied with:
storage case, 9V battery and mains plug (EU-type) (serial 5-/9-pin)

 

13-2127

 

PC-Data-Cable RS232 (PA)

RS232 data cable

for data transfer (serial 5-/9-pin)

 

11-0598

 

USB-Hub Device (4-ports) with power supply (EU-plug)

to connect 4 instruments by USB 2.0 to one PC USB-port, (Verified for petrotest® units)

 

11-0594

 

USB-Hub Device (4-ports) with power supply (US-plug-adapter)

 
Spare Parts   

13-1669

 

Oxidation Test Vessel Assembly - OBA-Safety

OBA 2 -Vessel Assembly

Consisting of:

Oxidation Test Vessel "OBA-Safety":
with burst disk, protection shield, needle valve and sample container

Pressure-peak damping device "Safety Kit"
with flame arrester, connecting line, manometer-terminal and filling valve

Digital Manometer PA5-OBA (14 bar):
with G1/4" male thread, supplied with PC-software "PetroNet standard",
USB-data transfer & power cable and Lithium 3.6 V battery.

 

13-2121

 

Digital Manometer PA5-OBA (precision made)

Digital Manometer PA5-OBA

suitable for: Oxidation Stability of
• Gasoline (Induction Period): ASTM D 525 - IP 40 - ISO 7536
• Diesel Fuel (Storage Stability): ASTM D 5304 (only with a tempering bath)
• Aviation Fuels (Potential Residue): ASTM D 873 - IP 138 - FTM 791b.3354

Features:
Programmable manometer with 4½ digit LCD, sample wetted materials made of stainless steel, FPM sealings, pressure connection at the bottom (G ¼" male thread).
For automatic determination of the Oxidation Stability, Induction Period, Potential Residue or Storage Stability with a OBA-oxidation vessel.

Supplied with:
PC-software "PetroNet standard", USB-data transfer & power cable, Lithium 3.6 V battery

Technical Data:
Pressure measurement range: 0 ... 14 bar / 1400 kPa / 203 psi
Temperature measurement range: 0 ... +200 °C / +32 ... +392 °F
Indication: pressure (bar / kPa / psi) and temperature (°C / °F)
Display resolution: 1 mbar / 0.1 °C
Internal data logging: 57 000 data sets
Connections: PC link / power cable, Pt1000 bath temperature sensor
Dimensions: Ø 75 mm x D 45 mm
Power supply: 5 ... 28 V / ∼3 mA (external), battery (internal)

 

13-2126

 

PC-Data-Cable USB (PA)

USB data & power cable

for data transfer & power supply (5-pin/USB)

 

13-2130

 

Rubber-Protection-Collar for PA-Manometer

 

13-1132

 

Battery, Lithium, 3.6 V (SL-760 with wire and plug)

fits: PA5-Manometer only (13-2121 / 17-1210 / 16-1970 etc.)

 

13-1137

 

Adapter (G ¼" female to M 10x1 male thread)

 

13-0525

 

Open-End Wrench Set (12, 17, 19, 24 and 27 mm)

 

17-0237

 

Hexagon Wrench (Allen Key), 2 mm

to adjust the dip-in depth of the vessel

 

13-0513

 

Sample Container & Cover , heat-resistant glass

 

21-0606

 

Thermometer ASTM 22C / IP 24C

Range: +95 to +103 : 0.1 °C
Length: 275 mm, Immersion: total, Ø 7 mm

 

13-0588

 

Burst Disc, 15 bar, including gasket (with certificate)

 

13-1149

 

O-Ring, for vessel, 54 x 3 mm, ( up to 200°C ), pack of 10

 

13-0524

 

Gaskets PTFE (11 x 6 x 2 mm), pack of 10

 

17-0234

 

Gaskets PTFE (25 x 13.5 x 2 mm), G ¼", pack of 10

 

17-0235

 

Gaskets PTFE (18 x 6 x 2 mm), G ½", pack of 10

 

13-0545

 

Pressure Line for oxygen supply

150 cm in length with couplings, EU-Version

 

13-0546

 

Heating Unit, 2000 W, 230 V

(two are used in dry-heat bath (13-1672))

 

25-0602

 

Heating Element DP, 2000 W, 230 V

 

13-1680

 

Support Shelf for 2 vessels (while not in use)

 
Order Guideline   

Minimum equipment:

1x Oxidation Test Arrangement

Spares (approx. 1 year):

13-0513, 21-0606, 13-1149, 13-0524, 17-0234, 17-0235

Additional requirements: