| Product |
Oxidation Characteristics of Distillate Fuel Oils - TOST- ASTM D 2274
| Main Unit |
16-0586 | Oxidation Cell Set |
|
![]() | ASTM D 943 / JIS K2514 (BS 4388) - ASTM D 2274 - ASTM D 4310 / IP 157 / JIS C2101 - ASTM D 7462 - ISO 4263 pt.1-3 - ISO 12 205 / IP 388 - DIN 51 587 |
|
16-0583 | Liquid Bath & Flow Meter Set (4-place & <6 l/h) |
|
![]() | ASTM D 943 / JIS K2514 (BS 4388) - ASTM D 2274 - ASTM D 4310 / IP 157 / JIS C2101 - ASTM D 7462 - ISO4263 - ISO 12 205 / IP 388 - DIN 51 587 - FTM 791-5308 (DIN 51 394) Consisting of: Power supply: 230 V, 50/60 Hz |
|
16-0584 | Liquid Bath & Flow Meter Set (4-place & <6 l/h) |
|
Like 16-0583 but: |
||
16-0581 | Liquid Bath & Flow Meter Set (8-place & <6 l/h) |
|
ASTM D 943 / JIS K2514 (BS 4388) - ASTM D 2274 - ASTM D 4310 / IP 157 / JIS C2101 - ASTM D 7462 - ISO4263 - ISO 12 205 / IP 388 - DIN 51 587 - FTM 791-5308 (DIN 51 394) Consisting of: Power supply: 230 V, 50/60 Hz |
||
16-0458 | Liquid Bath & Flow Meter Set (8-place & <6 l/h) |
|
Like 16-0581 but: |
||
16-0970 | Vacuum Filtration Assembly |
|
![]() | EN 12 662 - IP 440 Consisting of: Membran Filtration Apparatus: Vacuum System: |
|
| Options & Accessories |
16-0450 | Holder for 8 oil test tubes |
|
ASTM D 943 / JIS K2514 (BS 4388) - ASTM D 2274 - ASTM D 4310 / IP 157 / JIS C2101 - ASTM D 7462 - ISO4263 - ISO 12 205 / IP 388 - DIN 51 587 - FTM 791-5308 (DIN 51 394) |
||
16-0720 | Drain Cock for thermostatic baths (G¼") |
|
25-0515 | Bath Cooling Coil |
|
11-0092 | Thermometer ASTM 40C / IP 80C |
|
Range: +72 to +126 : 0.2 °C (officially certified) |
||
11-0093 | Thermometer ASTM 41C / IP 81C |
|
Range: +98 to +152 : 0.2 °C
|
||
11-0094 | Thermometer ASTM 41C / IP 81C |
|
Range: +98 to +152 : 0.2 °C (officially certified) |
||
11-0247 | Thermometer ASTM 102C / IP 83C |
|
Range: +123 to +177 : 0.2 °C
|
||
11-0248 | Thermometer ASTM 102C / IP 83C |
|
Range: +123 to +177 : 0.2 °C (officially certified) |
||
11-0249 | Thermometer ASTM 103C / IP 84C |
|
Range: +148 to +202 : 0.2 °C
|
||
11-0250 | Thermometer ASTM 103C / IP 84C |
|
Range: +148 to +202 : 0.2 °C (officially certified) |
||
| Spare Parts |
16-0589 | Oxygen Inlet Tube (Ø 7 x 750 mm) |
|
ASTM D 943 / JIS K2514 (BS 4388) - ASTM D 2274 - ASTM D 4310 / IP 157 / JIS C2101 - ASTM D 7462 - ISO 4263 pt.1-3 - ISO 12 205 / IP 388 - DIN 51 587 |
||
16-0588 | Condenser, Fungus-Type |
|
ASTM D 943 / JIS K2514 (BS 4388) - ASTM D 2274 - ASTM D 4310 / IP 157 / JIS C2101 - ASTM D 7462 - ISO 4263 pt.1-3 - ISO 12 205 / IP 388 - DIN 51 587 |
||
16-0590 | Test Tube (Ø 46 x 600 mm), round bottom |
|
ASTM D 943 / JIS K2514 (BS 4388) - ASTM D 2274 - ASTM D 4310 / IP 157 / JIS C2101 - ASTM D 7462 - ISO 4263 pt.1-3 - ISO 12 205 / IP 388 - DIN 51 587 |
||
16-0980 | Filter Membrane, 0.8 µm, Ø 50 mm, mixed ester (pack of 100) |
|
ASTM D 2274 - IP 388 - IP 440 - ISO 12 205 |
||
11-0091 | Thermometer ASTM 40C / IP 80C |
|
Range: +72 to +126 : 0.2 °C
|
||
25-0602 | Heating Element DP, 2000 W, 230 V |
|
25-0603 | Heating Element DP, 1000 W, 115 V |
|
16-0568 | Flow Meter-Unit, 0.4 ... 6 l/h |
|
![]() | Consisting of: |
|
| Order Guideline |
Minimum equipment: |
For 4-place: 1x Bath, 1x Accessories (see main unit) |
Spares (approx. 1 year): |
see Spare Parts: 4x (8x) Glassware, 1x Heating Element, Specimens (as necessary) |
Additional requirements: |
Gas Supply |